ISO 42001 for Medical Device Software: What It Adds

Clinician reviewing an AI-assisted scan next to AI governance icons, illustrating ISO/IEC 42001 for medical device software

ISO/IEC 42001:2023 (often shortened to ISO 42001) was published in December 2023 by ISO/IEC JTC 1/SC 42 as the first international standard for AI management systems. ISO/IEC 42006:2025, published in July 2025, sets additional requirements for the bodies that audit and certify against it. On 14 October 2026, Commission Implementing Decision (EU) 2026/2274 published the reference of EN 18286:2026, a quality management system standard for AI Act purposes, as a harmonised standard for high-risk AI systems. ISO/IEC 42001 is not that standard.

A manufacturer with an ISO 13485 QMS now has to decide what, if anything, ISO/IEC 42001 adds. This article covers what the standard is, how certification works, how it sits next to ISO 13485 and ISO/IEC 27001, and where AI Act Article 17 fits.

What ISO/IEC 42001 is

According to ISO, ISO/IEC 42001:2023:

  • sets requirements for establishing, implementing, maintaining and continually improving an AI management system (AIMS);

  • applies to organisations of any size and sector that develop, provide or use AI systems;

  • is a management system standard: it governs how the organisation manages AI, not how a specific AI product is built or tested;

  • is in its first edition and runs to 51 pages.

ISO also states that the standard does not replace laws or regulations (ISO/IEC 42001 explained).

In our view, ISO/IEC 42001 governs how an organisation manages AI. On its own, it does not show that a medical device or a high-risk AI system conforms to EU law.

The requirements at a glance

ISO lists the requirements of an AI management system as:

  • leadership and organisational context;

  • AI policy and objectives;

  • risk management for AI systems;

  • data governance and system lifecycle controls;

  • transparency and information provision;

  • performance evaluation and monitoring;

  • continual improvement.

For a SaMD manufacturer, several of these already have a home in the device QMS: design and change control, risk management, supplier control and post-market surveillance. In our view, the work is mostly in the AI-specific parts, such as an inventory of AI systems, data governance rules and model monitoring.

Certification

According to ISO:

  • certification to ISO/IEC 42001 is voluntary;

  • ISO does not certify organisations; independent certification bodies do, and they may be accredited by national accreditation bodies;

  • ISO/IEC 42006:2025 adds AI-specific requirements for those bodies and supplements ISO/IEC 17021-1.

A certificate covers the management system within its stated scope. Read the scope before relying on a supplier's or partner's certificate.

How it compares with the standards you already hold

Standard What it covers Certifiable? Role for an AI-enabled SaMD maker Source
ISO 13485:2016 Quality management system for medical devices, for regulatory purposes; confirmed in 2025 Yes, by certification bodies The backbone QMS for design, production and post-market obligations ISO
ISO/IEC 27001:2022 (Amd 1:2024) Information security management system Yes, by certification bodies Security of the information, systems and suppliers behind the device ISO
ISO/IEC 42001:2023 AI management system for organisations that develop, provide or use AI Yes, voluntary AI governance evidence beside the device QMS ISO
EN 18286:2026 Quality management system for EU AI Act regulatory purposes Harmonised standard under the AI Act The standards route for Article 17 for high-risk AI systems Decision (EU) 2026/2274

Sources: ISO pages for ISO 13485:2016, ISO/IEC 27001:2022 and ISO/IEC 42001:2023; Commission Implementing Decision (EU) 2026/2274.

ISO 13485 is about the device and the processes that bring it to market and keep it there. ISO/IEC 27001 is about information security. ISO/IEC 42001 is about how the organisation governs its use of AI, which can reach further than the device: AI tools in engineering, AI bought from suppliers, AI used internally.

An organisation can run these management systems side by side, with their own scopes. Our article on the ISO 13485 quality management system covers the device QMS, and our article on ISO/IEC 27001 requirements covers the ISMS.

In our view, the ISO 13485 QMS stays the backbone. ISO/IEC 42001 adds most where customers, hospitals or partners ask for AI governance evidence.

AI Act Article 17

Article 17(1) requires providers of high-risk AI systems to put a documented quality management system in place. It must include at least:

  • (a) a strategy for regulatory compliance, including conformity assessment and the management of modifications;

  • (b) design, design control and design verification;

  • (c) development, quality control and quality assurance;

  • (d) examination, test and validation procedures;

  • (e) technical specifications, including standards;

  • (f) data management;

  • (g) the risk management system under Article 9;

  • (h) post-market monitoring under Article 72;

  • (i) serious incident reporting under Article 73;

  • (j) communication with authorities, notified bodies, other operators and customers;

  • (k) record-keeping;

  • (l) resource management, including security of supply;

  • (m) an accountability framework for management and staff.

Implementation is proportionate to the size of the provider (Article 17(2)). Providers that already have quality management obligations under sectoral Union law may include these aspects in that QMS (Article 17(3)). For a medical device manufacturer, that is the MDR or IVDR quality management system.

The AI Act Service Desk marks Article 17 as amended by the Digital Omnibus on AI, so work from the current text. Whether a device is a high-risk AI system in the first place is covered in our article on the EU AI Act for medical devices.

EN 18286:2026 and presumption of conformity

Decision (EU) 2026/2274 is dated 12 October 2026 and entered into force on its publication on 14 October 2026. Its annex lists one standard: EN 18286:2026, "Artificial intelligence – Quality management system for EU AI Act regulatory purposes". It follows the Commission's standardisation request C(2025) 3871.

According to the Commission, applying standards remains voluntary, and companies that apply harmonised standards referenced in the Official Journal are presumed to comply with the requirements they cover.

The Commission also explains why ISO/IEC 42001 was not used for this purpose. In its standardisation FAQ, it states that ISO/IEC 42001:2023 helps to set up an AI management system, but its goals and definitions are not aligned with the quality management system required under the AI Act. That is why a new standard was requested.

In our view, with EN 18286:2026 now cited, check the Article 17 route against that standard, not against ISO/IEC 42001. We wrote about the standard while it was still a draft in our article on prEN 18286.

A hypothetical example

Hypothetical example: a Dutch company holds ISO 13485 and ISO/IEC 27001 certificates and CE-marks an AI-enabled software device. A hospital customer asks for evidence of AI governance.

  1. Scope: it defines the AIMS scope and lists the AI systems inside it.

  2. Mapping: it maps the seven requirement areas to procedures it already runs, such as design control, change control, risk management, supplier control and post-market surveillance.

  3. Gaps: it adds what is missing for AI, such as data governance rules and model monitoring.

  4. Certification: it chooses a certification body working to ISO/IEC 42006.

  5. Article 17: if the device is a high-risk AI system, it looks to EN 18286:2026 and integrates the Article 17 aspects into its existing QMS under Article 17(3).

  6. MDR: its technical documentation remains the conformity evidence for the device.

Conclusion

ISO/IEC 42001 is a voluntary, certifiable standard for managing AI across an organisation. It is not a harmonised standard under the AI Act, and it does not replace ISO 13485 or the MDR and IVDR obligations.

In our view, keep the ISO 13485 QMS as the backbone, use EN 18286:2026 for the Article 17 route, and add ISO/IEC 42001 where customers or partners ask for AI governance evidence.

If you need help deciding whether an AI management system belongs beside your device QMS, our management system team can help, or contact MedQAIR.

Frequently asked questions

Is ISO/IEC 42001 mandatory?

No. Certification is voluntary, and Article 17 of the AI Act does not refer to it.

Is ISO/IEC 42001 a harmonised standard under the AI Act?

No. Decision (EU) 2026/2274 lists one standard, EN 18286:2026.

Can an organisation be certified to ISO/IEC 42001?

Yes. Certification is voluntary and is carried out by independent certification bodies.

Does ISO/IEC 42001 replace ISO 13485?

No. ISO 13485 is the quality management system for medical devices for regulatory purposes. ISO/IEC 42001 covers how an organisation manages AI.

Who certifies against ISO/IEC 42001?

Independent certification bodies, which may be accredited by national accreditation bodies. ISO/IEC 42006:2025 sets additional requirements for them.

Latest Blogs

November 26, 2026

ISO/IEC 42001:2023 (often shortened to ISO 42001) was published in December 2023 by ISO/IEC JTC 1/SC 42 as the first

November 25, 2026

ISO 14971:2019, the third edition, was published in December 2019 and confirmed in 2025. FDA recognised it in full on

November 24, 2026

Canada's Medical Devices Regulations (SOR/98-282) sort devices into Classes I to IV (section 6). Since 1 January 2019, MDSAP has

logo

Unlock Your Quick Guide to AI Act
Compliance!

Explore AI-enabled SaMD requirements with our easy step-by-step guide.

Cookies help us improve your experience on our website. By using our site, you consent to the use of cookies as described in this policy.